Our solutions
Find the right method to perform this assay
This website is now available in Brazilian Portuguese, French, German, Italian, Polish, Portuguese and Spanish. You can choose your language in the top right corner.
INNOVATIVE DIAGNOSTIC SOLUTIONS
Obtain clear, specific antibody breakdowns for your samples efficiently and confidently.
If unexpected antibodies are detected in a sample, rapid and safe identification is essential for your lab.
When Antibody identification is needed as part of your routine pretransfusion testing Grifols has everything you need.
Find the right method to perform this assay
Gel card technology
Conventional techniques
DG Gel cards are the original 8-column agglutination technology (CAT). DG Gel cards paired with high-quality reagents facilitate efficient antibody identification in any workflow. Screen blood quickly and safely for antibodies, common and rare and in all testing configurations. DG Gel cards and wide selection of rRBC deliver efficient results for every lab and can grow as your volume increases.
210342
DG Gel Coombs
With DG Gel Coombs flexible testing is simple with one versatile card for many tests. Antibody screening & identification, crossmatch testing, autocontrol, red blood cell typing and direct coombs test can be performed on DG Gel Coombs card.
Configuration:
AHG | AHG | AHG | AHG | AHG | AHG | AHG | AHG
210343
DG Gel Neutral
Obtain loads of information using the 8 buffered gel medium to perform saline and enzymatic techniques to investigate unexpected antibodies such as screening, identification, crossmatch, and autocontrol.
Configuration:
N | N | N | N | N | N | N | N
210375
DG Gel Neutral/Coombs
Indirect and direct testing of saline and enzymatic tests, as well as antibody screening, identification, crossmatch testing, auto control and red blood cell typing all on one card gives you the flexibility to test your way.
Configuration:
N | N | N | N | AHG | AHG | AHG | AHG
210344
DG Gel Anti-IgG
DG Gel Anti-IgG gives you antibody detection and identification monospecific testing that fits your needs. Further characterization of the antibody is easy with DG Gel Anti-IgG.
Configuration:
IgG | IgG | IgG | IgG | IgG | IgG | IgG | IgG
Identisera Diana Red Blood Cells
Identify common and rare clinically significant antibodies with a flexible format of 11 or 15 ready-to-use red blood cells. Identisera Diana panels are available untreated and papainized so you can mix and match rRBCs to optimize your analysis.
Data-Cyte Plus 0.8% Red Blood Cells
Identify common and rare clinically significant antibodies with a flexible format of 11, 12, 15 or 16 ready-to-use red blood cells. Data-Cyte Plus 0.8% panels are available untreated and papainized so you can mix and match rRBCs to optimize your analysis.
Identisera Diana
210210
11-cell identification panel
Identisera Diana Extend
210212
4-cell identification panel to be added to Identisera Diana
Data-Cyte Plus 0.8%
213587
11-cell identification panel
Data-Cyte Plus Dia 0.8%
213627
12-cell identification panel including Dia antigen
Data-Cyte Extend 0.8%
213685
4-cell panel of 4 Rh(D) negative donors to be used alone or complementing Data-Cyte Plus 0.8% panels
Diego(a)-Cyte 0.8%
213802
Dia antigen positive cell
Mi(a)-Cyte 0.8%
213386
Mia antigen positive cell
Identisera Diana P
210211
Papainized 11-cell identification panel
Identisera Diana Extend P
210213
Papainized 4-cell identification panel to be added to Identisera Diana P
Data-Cyte Plus P 0,8%
213661
Papainized 11-cell identification panel
Name | Code | Description |
---|---|---|
Identisera Diana |
210210 |
11-cell identification panel |
Identisera Diana Extend |
210212 |
4-cell identification panel to be added to Identisera Diana |
Data-Cyte Plus 0.8% |
213587 |
11-cell identification panel |
Data-Cyte Plus Dia 0.8% |
213627 |
12-cell identification panel including Dia antigen |
Data-Cyte Extend 0.8% |
213685 |
4-cell panel of 4 Rh(D) negative donors to be used alone or complementing Data-Cyte Plus 0.8% panels |
Diego(a)-Cyte 0.8% |
213802 |
Dia antigen positive cell |
Mi(a)-Cyte 0.8% |
213386 |
Mia antigen positive cell |
Identisera Diana P |
210211 |
Papainized 11-cell identification panel |
Identisera Diana Extend P |
210213 |
Papainized 4-cell identification panel to be added to Identisera Diana P |
Data-Cyte Plus P 0,8% |
213661 |
Papainized 11-cell identification panel |
Essential II Control
213287
Quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique
Extended IV Control
213286
Quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique
Bromelase 30
213578
Proteolytic enzyme used to supplement standard procedures by enhancing the reactivity of some antibodies and inhibit others in antibody screening, identification and crossmatch in gel and tube techniques
DG Fluid A
213679
Solutions used for the washing of the Grifols instruments' fluidic system
DG Fluid B
213678
Solutions used for the washing of the Grifols instruments' fluidic system
Name | Code | Description |
---|---|---|
Essential II Control |
213287 |
Quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique |
Extended IV Control |
213286 |
Quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique |
Bromelase 30 |
213578 |
Proteolytic enzyme used to supplement standard procedures by enhancing the reactivity of some antibodies and inhibit others in antibody screening, identification and crossmatch in gel and tube techniques |
DG Fluid A |
213679 |
Solutions used for the washing of the Grifols instruments' fluidic system |
DG Fluid B |
213678 |
Solutions used for the washing of the Grifols instruments' fluidic system |
Whether you are utilizing conventional tube reagents for most of your testing or for resolving problematic cases, it is important to have a wide range of reagent red blood cells and antisera to meet your needs.
Simplifying antibody identification procedures for conventional serology is easy with our extensive range of reagents.
Anti-Human Globulin Mono-Type
213423
Polyspecific Coombs reagent to detect immunoglobulin and /or complement bound to red blood cells in direct and indirect antiglobulin tests
Anti-IgG
213559
Monospecific Coombs reagent for indirect antiglobulin tests to differentiate between IgG and complement sensitization
Data-Cyte Plus 3%
213392
11-cell identification panel
Data-Cyte Plus Dia 3%
213626
12-cell identification panel including Dia antigen
Diego(a)-Cyte 3%
213803
Dia antigen positive cell
Name | Code | Description |
---|---|---|
Anti-Human Globulin Mono-Type |
213423 |
Polyspecific Coombs reagent to detect immunoglobulin and /or complement bound to red blood cells in direct and indirect antiglobulin tests |
Anti-IgG |
213559 |
Monospecific Coombs reagent for indirect antiglobulin tests to differentiate between IgG and complement sensitization |
Data-Cyte Plus 3% |
213392 |
11-cell identification panel |
Data-Cyte Plus Dia 3% |
213626 |
12-cell identification panel including Dia antigen |
Diego(a)-Cyte 3% |
213803 |
Dia antigen positive cell |
Coombs Control
213394
Positive control for antiglobulin tests based on red cells sensitized with humnan IgG antibodies
Essential II Control
213287
Quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique
Extended IV Control
213286
Quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique
Specific Albumin 22%
213422
Complementary solution to enhance the antigen-antibody reaction of compatibility testing, antibody screening, identification and titration
Specific Albumin 30%
213573
Complementary solution to enhance the antigen-antibody reaction of compatibility testing, antibody screening, identification and titration
ENLISST-II
213577
Low Ionic Strength Solution used to enhance antigen-antibody reactions in tube procedures such as compatibility testing, antibody screening and identification
Bromelase 30
213578
Proteolytic enzyme used to supplement standard procedures by enhancing the reactivity of some antibodies and inhibit others in antibody screening, identification and crossmatch in gel and tube techniques
Name | Code | Description |
---|---|---|
Coombs Control |
213394 |
Positive control for antiglobulin tests based on red cells sensitized with humnan IgG antibodies |
Essential II Control |
213287 |
Quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique |
Extended IV Control |
213286 |
Quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique |
Specific Albumin 22% |
213422 |
Complementary solution to enhance the antigen-antibody reaction of compatibility testing, antibody screening, identification and titration |
Specific Albumin 30% |
213573 |
Complementary solution to enhance the antigen-antibody reaction of compatibility testing, antibody screening, identification and titration |
ENLISST-II |
213577 |
Low Ionic Strength Solution used to enhance antigen-antibody reactions in tube procedures such as compatibility testing, antibody screening and identification |
Bromelase 30 |
213578 |
Proteolytic enzyme used to supplement standard procedures by enhancing the reactivity of some antibodies and inhibit others in antibody screening, identification and crossmatch in gel and tube techniques |
Accelerate pre-transfusion testing with Grifols' comprehensive typing, screening & identification assays.