DONOR SCREENING

Procleix Panther System Featuring ART

Optimize variable workflow needs through superior customization with easy, scalable options that help transform the way your lab works as your needs evolve.

Procleix Panther System Featuring ART

Procleix Panther System Featuring ART

Get enhanced levels of automation for laboratories in a compact footprint without compromising throughput.  It combines the proven and reliable performance of the Procleix Panther System with software and hardware improvements to build upon our NAT screening solution. Innovative optional components, such as full track connectivity and remote monitoring, can be installed to optimize variable workflow needs now or in the future.

Main benefits

Superior customization

Prioritize the way you work and improve your throughput with a faster turnaround time giving you more flexibility for planning variable workflows and peak loads while saving valuable floor space.

Innovative optional components

Add a remote dashboard, data sharing, expansion packs and more at any time to meet present or future needs, without compromising quality or performance.

Streamlined workflow

Streamline lab workflow with continuous testing and release of results, true STAT for priority samples, 24-hour calibration, and no end-of-run controls.

The Panther of the Future

Meet the next great addition to your team. Discover the exciting benefits to the system that grows with you and brings a new level of automation to your lab.

Innovation that Empowers

Discover the innovative evolution of the Procleix Panther System Featuring ART for everything you know and love about the Procleix Panther System now with integrated technology to maximize automation and allow for easy scalability.

Product specifications

Product Detail
Specifications
  • Instrument: 122 x 81.5 x 175 cm
  • Instrument with MTU Expansion Module: 149 x 81.5 x 175 cm
Additional features
  • UPS: 21.4 x 41 x 32.5 cm
  • Direct-to-drain pump: 24 x 22 x 23 cm
Specifications
  • Base: 183 x 172.9 x 198 cm
  • With MTU Expansion Module: 214 x 172.9 x 198 cm
Additional features
  • No need for rear clearance, instrument can be installed directly against a wall
Specifications
  • Base: 363 kg
  • UPS: 34.5 kg
Additional features
  • With MTU Expansion Module: 423 kg
Specifications
  • Up to 120 sample tubes (8 racks) + on-demand access*
Additional features
Specifications
  • Up to 2000 tests (4 sets) + on-demand access*
Additional features
Specifications
  • Up to 2000 tests (2 sets) + on-demand access*
Additional features
Specifications
  • MTU: Up to 125 tests + on-demand access*
  • Tips: Up to 576
Additional features
  • MTU (with MTU Expansion Module): Up to 600 tests + on-demand access*
Specifications
  • Base model: Up to 750 tests + on-demand access*
Additional features
  • With optional direct-to-drain: No limit**
Specifications
  • Up to 750 tests + on-demand access*
Additional features
Specifications
  • 3.5 hr to first 5 results; 5 results every 5 min thereafter
Additional features
  • 275 test results in 8 hr; up to 500 test results in 12 hr
Specifications
  • Code 39, Code 93, Code 128 (ISBT 128), Interleaved 2 of 5, Codabar, Jan 13, UPC
Additional features
Specifications
  • Up to 24 hours
Additional features
Specifications
  • Up to 60 (also non-continuous) hours
Additional features
Specifications
  • Altitude: Equal to or less than 2000 m above sea level
  • Operational temperature: 15–30°C
Additional features
  • Operational humidity: 20–85% relative (non-condensing) at 30°C or below
Specifications
  • Electrical input: 100–240; VAC: (± 10%), 50/60 Hz: single phase
  • Current input: 110 V - 20 amp circuit (dedicated if used with optional UPS) specified to operate at a minimum of 15 amps (dedicated); 220 V - 10 amp circuit (dedicated) specified to operate at 7.5 amps (dedicated)
  • Current draw: Draw 1400 W peak, average 700 W (13 amps @ 100 VAC, 5.4 amps @ 240 VAC)
Additional features
Specifications
  • Heat dissipation: 550 W (1878 BTU/hr) during steady state
  • Drain output: Waste fluids drain to removable containers, or directly to centralized laboratory drainage system**
  • Noise output: <60 dB(A)
Additional features
Specifications
  • Microsoft Windows 10
Additional features
Specifications
  • Up to 120 MTU capacity (up to 600 tests)
Additional features
Specifications
  • Data sharing among up to 16 connected instruments
  • Exchange partially utilized reagent kits among connected instruments
  • Single user login and setup across networked instruments
  • Duplicate-sample prevention across networked instruments
Additional features
Specifications
  • Provides real-time status of networked Procleix Panther systems featuring ART that can be displayed via TV screen monitor, tablet, or desktop PC***
Additional features

* Allows operator access during system operation; certain restrictions apply
** For instruments equipped with optional direct-to-drain pump. Please refer to your local environmental regulations and guidelines
*** Up to 16 Procleix Panther systems featuring ART can be connected; 6 can be displayed at a time

Product Detail Specifications Additional features

Physical dimensions (WxDxH)

  • Instrument: 122 x 81.5 x 175 cm
  • Instrument with MTU Expansion Module: 149 x 81.5 x 175 cm
  • UPS: 21.4 x 41 x 32.5 cm
  • Direct-to-drain pump: 24 x 22 x 23 cm

Minimum clearance requirements

  • Base: 183 x 172.9 x 198 cm
  • With MTU Expansion Module: 214 x 172.9 x 198 cm
  • No need for rear clearance, instrument can be installed directly against a wall

Weight

  • Base: 363 kg
  • UPS: 34.5 kg
  • With MTU Expansion Module: 423 kg

Sample capacity

  • Up to 120 sample tubes (8 racks) + on-demand access*

Reagent capacity

  • Up to 2000 tests (4 sets) + on-demand access*

Fluid capacity

  • Up to 2000 tests (2 sets) + on-demand access*

Consumables capacity

  • MTU: Up to 125 tests + on-demand access*
  • Tips: Up to 576
  • MTU (with MTU Expansion Module): Up to 600 tests + on-demand access*

Liquid waste capacity

  • Base model: Up to 750 tests + on-demand access*
  • With optional direct-to-drain: No limit**

Solid waste capacity

  • Up to 750 tests + on-demand access*

Sample throughput

  • 3.5 hr to first 5 results; 5 results every 5 min thereafter
  • 275 test results in 8 hr; up to 500 test results in 12 hr

Sample barcode types

  • Code 39, Code 93, Code 128 (ISBT 128), Interleaved 2 of 5, Codabar, Jan 13, UPC

System calibration

  • Up to 24 hours

On-board reagent stability

  • Up to 60 (also non-continuous) hours

Environmental requirements

  • Altitude: Equal to or less than 2000 m above sea level
  • Operational temperature: 15–30°C
  • Operational humidity: 20–85% relative (non-condensing) at 30°C or below

Electrical requirements

  • Electrical input: 100–240; VAC: (± 10%), 50/60 Hz: single phase
  • Current input: 110 V - 20 amp circuit (dedicated if used with optional UPS) specified to operate at a minimum of 15 amps (dedicated); 220 V - 10 amp circuit (dedicated) specified to operate at 7.5 amps (dedicated)
  • Current draw: Draw 1400 W peak, average 700 W (13 amps @ 100 VAC, 5.4 amps @ 240 VAC)

Environmental output

  • Heat dissipation: 550 W (1878 BTU/hr) during steady state
  • Drain output: Waste fluids drain to removable containers, or directly to centralized laboratory drainage system**
  • Noise output: <60 dB(A)

Operating system

  • Microsoft Windows 10

MTU Expansion Module (optional)

  • Up to 120 MTU capacity (up to 600 tests)

Data sharing (optional)

  • Data sharing among up to 16 connected instruments
  • Exchange partially utilized reagent kits among connected instruments
  • Single user login and setup across networked instruments
  • Duplicate-sample prevention across networked instruments

Dashboard (optional)

  • Provides real-time status of networked Procleix Panther systems featuring ART that can be displayed via TV screen monitor, tablet, or desktop PC***