Antibody Identification (CE Approved)
Obtain clear, specific antibody breakdowns for your samples efficiently and confidently.
Antibody Identification
If unexpected antibodies are detected in a sample, rapid and safe identification is essential for your lab.
When Antibody identification is needed as part of your routine pretransfusion testing Grifols has everything you need.
Our solutions
Find the right method to perform this assay
Gel card technology
DG Gel cards organize your antibody investigation and make testing efficient no matter the size of your lab
DG Gel cards are the original 8-column agglutination technology (CAT). DG Gel cards paired with high-quality reagents facilitate efficient antibody identification in any workflow. Screen blood quickly and safely for antibodies, common and rare and in all testing configurations. DG Gel cards and wide selection of rRBC deliver efficient results for every lab and can grow as your volume increases.
DG Gel Cards for this assay
Reagents for this assay
- Code
210210
- Description
11-cell identification panel
- Code
210212
- Description
4-cell identification panel to be added to Identisera Diana
- Code
213587
- Description
11-cell identification panel
- Code
213685
- Description
4-cell panel of 4 Rh(D) negative donors to be used alone or complementing Data-Cyte Plus 0.8% panels
- Code
213802
- Description
Dia antigen positive cell
- Code
213386
- Description
Mia antigen positive cell
- Code
210211
- Description
Papainized 11-cell identification panel
- Code
210213
- Description
Papainized 4-cell identification panel to be added to Identisera Diana P
- Code
213661
- Description
Papainized 11-cell identification panel
| Name | Code | Description |
|---|---|---|
|
Identisera Diana |
210210 |
11-cell identification panel |
|
Identisera Diana Extend |
210212 |
4-cell identification panel to be added to Identisera Diana |
|
Data-Cyte Plus 0.8% |
213587 |
11-cell identification panel |
|
Data-Cyte Extend 0.8% |
213685 |
4-cell panel of 4 Rh(D) negative donors to be used alone or complementing Data-Cyte Plus 0.8% panels |
|
Diego(a)-Cyte 0.8% |
213802 |
Dia antigen positive cell |
|
Mi(a)-Cyte 0.8% |
213386 |
Mia antigen positive cell |
|
Identisera Diana P |
210211 |
Papainized 11-cell identification panel |
|
Identisera Diana Extend P |
210213 |
Papainized 4-cell identification panel to be added to Identisera Diana P |
|
Data-Cyte Plus P 0,8% |
213661 |
Papainized 11-cell identification panel |
Quality Controls and complementary solutions for this assay:
- Code
213287
- Description
Dual use quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique
- Code
213286
- Description
Dual use quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique
- Code
213578
- Description
Proteolytic enzyme used to supplement standard procedures by enhancing the reactivity of some antibodies and inhibit others in antibody screening, identification and crossmatch in gel and tube techniques
- Code
213679
- Description
Solutions used for the washing of the Grifols instruments' fluidic system
- Code
213678
- Description
Solutions used for the washing of the Grifols instruments' fluidic system
| Name | Code | Description |
|---|---|---|
|
Essential II Control |
213287 |
Dual use quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique |
|
Extended IV Control |
213286 |
Dual use quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique |
|
Bromelase 30 |
213578 |
Proteolytic enzyme used to supplement standard procedures by enhancing the reactivity of some antibodies and inhibit others in antibody screening, identification and crossmatch in gel and tube techniques |
|
DG Fluid A |
213679 |
Solutions used for the washing of the Grifols instruments' fluidic system |
|
DG Fluid B |
213678 |
Solutions used for the washing of the Grifols instruments' fluidic system |
Conventional techniques
Conventional reagents that are a proven and reliable solution for every type of lab
Whether you are utilizing conventional tube reagents for most of your testing or for resolving problematic cases, it is important to have a wide range of reagent red blood cells and antisera to meet your needs.
Simplifying antibody identification procedures for conventional serology is easy with our extensive range of reagents.
Reagents for this assay
- Code
210935
- Description
Polyspecific Coombs reagent to detect immunoglobulin and /or complement bound to red blood cells in direct and indirect antiglobulin tests
- Code
213559
- Description
Monospecific Coombs reagent for indirect antiglobulin tests to differentiate between IgG and complement sensitization
- Code
213392
- Description
11-cell identification panel
- Code
213803
- Description
Dia antigen positive cell
| Name | Code | Description |
|---|---|---|
|
Anti-Human Globulin Polyspecific |
210935 |
Polyspecific Coombs reagent to detect immunoglobulin and /or complement bound to red blood cells in direct and indirect antiglobulin tests |
|
Anti-IgG |
213559 |
Monospecific Coombs reagent for indirect antiglobulin tests to differentiate between IgG and complement sensitization |
|
Data-Cyte Plus 3% |
213392 |
11-cell identification panel |
|
Diego(a)-Cyte 3% |
213803 |
Dia antigen positive cell |
Quality Controls and complementary solutions for this assay:
- Code
213394
- Description
Positive control for antiglobulin tests based on red cells sensitized with humnan IgG antibodies
- Code
213287
- Description
Dual use quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique
- Code
213286
- Description
Dual use quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique
- Code
213422
- Description
Complementary solution to enhance the antigen-antibody reaction of compatibility testing, antibody screening, identification and titration
- Code
213573
- Description
Complementary solution to enhance the antigen-antibody reaction of compatibility testing, antibody screening, identification and titration
- Code
213577
- Description
Low Ionic Strength Solution used to enhance antigen-antibody reactions in tube procedures such as compatibility testing, antibody screening and identification
- Code
213578
- Description
Proteolytic enzyme used to supplement standard procedures by enhancing the reactivity of some antibodies and inhibit others in antibody screening, identification and crossmatch in gel and tube techniques
| Name | Code | Description |
|---|---|---|
|
Coombs Control |
213394 |
Positive control for antiglobulin tests based on red cells sensitized with humnan IgG antibodies |
|
Essential II Control |
213287 |
Dual use quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique |
|
Extended IV Control |
213286 |
Dual use quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique |
|
Specific Albumin 22% |
213422 |
Complementary solution to enhance the antigen-antibody reaction of compatibility testing, antibody screening, identification and titration |
|
Specific Albumin 30% |
213573 |
Complementary solution to enhance the antigen-antibody reaction of compatibility testing, antibody screening, identification and titration |
|
ENLISST-II |
213577 |
Low Ionic Strength Solution used to enhance antigen-antibody reactions in tube procedures such as compatibility testing, antibody screening and identification |
|
Bromelase 30 |
213578 |
Proteolytic enzyme used to supplement standard procedures by enhancing the reactivity of some antibodies and inhibit others in antibody screening, identification and crossmatch in gel and tube techniques |
Downloadable resources
Explore other Blood Typing Tests
Accelerate pre-transfusion testing with Grifols' comprehensive typing, screening & identification assays.