Weak D (CE Approved)
Detecting weak D antigen can prove frustrating our testing solutions make elusive results simple and clear.
Weak D
Sometimes low quantities of the D antigen on red cells can mean you might have a false D negative result. With one reagent that can be utilized for both tube and gel technologies optimize your resources for serology testing.
Our solutions
Find the right method to perform this assay
Gel card technology
Organize your Weak D testing and make testing efficient no matter the size of your lab
With DG Gel cards you can identify your Weak D patients and utilize Human Rho(D) immune globulin and transfuse with confidence.
Detect Weak D with Anti-D antisera and DG Gel cards used together in manual, semi-automated and fully automated. Weak D Grifols DG Gel solutions is highly specific and sensitive for reliable testing.
DG Gel Cards for this assay
Antisera to be used in DG Gel cards:
Quality Controls and complementary solutions for this assay:
- Code
213561
- Description
Dual-use weak positive control with a confirmed weak expression of the RhD antigen to be used in parallel with D typing tests either using DG Gel System or tube technique.
- Code
213287
- Description
Dual use quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique
- Code
213286
- Description
Dual use quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique
- Code
210354
- Description
Reagent used for suspending red blood cells and diluting plasma or serum samples.
- Code
213797
- Description
Solution for cleaning the probes of Grifols instruments.
- Code
213679
- Description
Solutions used for the washing of the Grifols instruments' fluidic system.
- Code
213678
- Description
Solutions used for the washing of the Grifols instruments' fluidic system.
| Name | Code | Description |
|---|---|---|
|
Weak D Control |
213561 |
Dual-use weak positive control with a confirmed weak expression of the RhD antigen to be used in parallel with D typing tests either using DG Gel System or tube technique. |
|
Essential II Control |
213287 |
Dual use quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique |
|
Extended IV Control |
213286 |
Dual use quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique |
|
DG Gel Sol |
210354 |
Reagent used for suspending red blood cells and diluting plasma or serum samples. |
|
DG Clean |
213797 |
Solution for cleaning the probes of Grifols instruments. |
|
DG Fluid A |
213679 |
Solutions used for the washing of the Grifols instruments' fluidic system. |
|
DG Fluid B |
213678 |
Solutions used for the washing of the Grifols instruments' fluidic system. |
Conventional techniques
Conventional reagents that are a proven and reliable solution for every type of lab
Antisera that are a proven and reliable solution for every type of lab.
Whether you are utilizing conventional tube reagents for most of your testing or for resolving problematic cases, it is important to have a wide range of antisera to meet your needs.
Reagents for this assay
- Code
210922
- Description
Mix of IgM and IgG antisera to identify the RhD antigen including the detection of most types of weak Rh(D) and partial DVI using tube technique
- Code
210935
- Description
Polyspecific Coombs reagent to detect immunoglobulin and /or complement bound to red blood cells in direct and indirect antiglobulin tests.
- Code
213559
- Description
Monospecific Coombs reagent for indirect antiglobulin tests to differentiate between IgG and complement sensitization.
| Name | Code | Description |
|---|---|---|
|
Anti-D Combi Mono-Type |
210922 |
Mix of IgM and IgG antisera to identify the RhD antigen including the detection of most types of weak Rh(D) and partial DVI using tube technique |
|
Anti-Human Globulin Polyspecific |
210935 |
Polyspecific Coombs reagent to detect immunoglobulin and /or complement bound to red blood cells in direct and indirect antiglobulin tests. |
|
Anti-IgG |
213559 |
Monospecific Coombs reagent for indirect antiglobulin tests to differentiate between IgG and complement sensitization. |
Quality Controls and complementary solutions for this assay:
- Code
213394
- Description
Positive control for antiglobulin tests based on red cells sensitized with human IgG antibodies.
- Code
210933
- Description
Negative quality control reagent for parallel testing in tube technique with Grifols monoclonal blood grouping antisera including ABO, Rh (C, c, E, e), Kidd, and Lewis; presentation: 6 × 5 mL.
- Code
210934
- Description
Negative quality control reagent for parallel testing in tube technique with Grifols monoclonal blood grouping antisera including ABO, Rh (C, c, E, e), Kidd, and Lewis; presentation: 1 × 5 mL.
- Code
213561
- Description
Dual use weak positive control with a confirmed weak expression of the RhD antigen to be used in parallel with D typing tests either using DG Gel System or tube technique
- Code
213287
- Description
Dual use quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique.
- Code
213286
- Description
Dual use quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique.
- Code
213422
- Description
Complementary solution to enhance the antigen-antibody reaction of compatibility testing, antibody screening, identification and titration.
- Code
213573
- Description
Complementary solution to enhance the antigen-antibody reaction of compatibility testing, antibody screening, identification and titration.
| Name | Code | Description |
|---|---|---|
|
Coombs Control |
213394 |
Positive control for antiglobulin tests based on red cells sensitized with human IgG antibodies. |
|
Antisera Control |
210933 |
Negative quality control reagent for parallel testing in tube technique with Grifols monoclonal blood grouping antisera including ABO, Rh (C, c, E, e), Kidd, and Lewis; presentation: 6 × 5 mL. |
|
Antisera Control |
210934 |
Negative quality control reagent for parallel testing in tube technique with Grifols monoclonal blood grouping antisera including ABO, Rh (C, c, E, e), Kidd, and Lewis; presentation: 1 × 5 mL. |
|
Weak D Control |
213561 |
Dual use weak positive control with a confirmed weak expression of the RhD antigen to be used in parallel with D typing tests either using DG Gel System or tube technique |
|
Essential II Control |
213287 |
Dual use quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique. |
|
Extended IV Control |
213286 |
Dual use quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique. |
|
Specific Albumin 22% |
213422 |
Complementary solution to enhance the antigen-antibody reaction of compatibility testing, antibody screening, identification and titration. |
|
Specific Albumin 30% |
213573 |
Complementary solution to enhance the antigen-antibody reaction of compatibility testing, antibody screening, identification and titration. |
Molecular technology
Go beyond serological testing for your most complex cases
Enhance your ability to confirm the Rh(D) negative donors, rationalize the use of RhIG injections for pregnant women as well as the use of Rh(D) neg blood units for patients with BLOODchip ID RHD XT. Predict the RhD phenotype that cannot be resolved by serology and benefit from knowing the patient's or donor's genotype with a user-friendly streamlined workflow ready in just 4 hours and that only requires 30 minutes of hands-on time.
Downloadable resources
Explore other Blood Typing Tests
Accelerate pre-transfusion testing with Grifols' comprehensive typing, screening & identification assays.