Our solutions
Find the right method to perform this assay
This website is available in Brazilian Portuguese, German, Italian, Polish, Portuguese and Spanish. You can choose your language in the top right corner. The French language version is currently unavailable.
INNOVATIVE DIAGNOSTIC SOLUTIONS
Tailor your ABO &Rh testing to your lab with complete freedom and reliability.
Grifols offers standard and reliable ABO/Rh testing using gel technology and conventional techniques. Additionally, genotyping is available to detect clinically relevant RhD variants and confirm RhD negative results.
Find the right method to perform this assay
Gel card technology
Conventional techniques
Molecular technology
DG Gel gives you a seamless transition to greater complexity and a higher volume of testing. With an original 8-well format, DG Gel cards give you the flexibility to test any number of ABO & Rh combinations on a single card, including always the control well together with RhD determination. Whether you test manually, semi-automated, or fully automated, DG Gel cards keep your test flow organized and efficient.
210355
DG Gel ABO/Rh
A single card that gives you full ABO and Rh(D) testing with reverse group confirmation.
Configuration:
A | B | AB | DVI- | CDE | CTL | N | N
210126
DG Gel ABO/Rh (2D) (RT)
A DG Gel card that gives you full ABO/Rh forward and reverse with detection of partial DVI.
Configuration:
A | B | AB | DVI- | DVI+ | CTL | N | N
210352
DG Gel ABO/Rh + Kell (RT)
A single DG Gel card with ABO/Rh(D) and Kell typing allows for complete forward and reverse.
Configuration:
A | B | AB | Dᵛᴵ⁻ | K | CTL | N | N
210378
DG Gel ABO/Rh (CR)
Seamless prenatal, perinatal and routine ABO/Rh testing with a card that gives you full ABO and Rh(D) and reverse group confirmation with the detection of Kell antigens.
Configuration:
A | B | DVI- | DVI- | K | CTL | N | N
210340
DG Gel ABO-CDE
Fully test ABO and Rh (C D E) with reverse group confirmation on a single card.
Configuration:
A | B | DVI- | C | E | CTL | N | N
210353
DG Gel Newborn
Enhance your newborn ABO/Rh testing with DG Gel Newborn. This gel card allows you to test expand ABO group, Rh(D) with detection of partial DVI and direct coombs.
Configuration:
A | B | AB | DVI- | DVI+ | CTL | IgG | AHG
210339
DG Gel Confirm
Easily add DVI+ testing to your ABO forward typing with DG Gel Confirm. Two on one testing of ABO and DVI+ allows you to offer greater complexity testing.
Configuration:
A | B | DVI+ | CTL | A | B | DVI+ | CTL
210351
DG Gel Confirm P
Efficient ABO forward typing with two on one testing gives you flexible ABO group confirmation wether testing manually, semi-automated, or fully automated.
Configuration:
A | B | DVI- | CTL | A | B | DVI- | CTL
210341
DG Gel Anti-D
RhD testing that enhances your lab. DG Gel anti-D gives you the confidence that DVI variants are assessed with a monoclonal mixture of IgG and IgM antibodies against D and DVI variants.
Configuration:
DVI+ | CTL | DVI+ | CTL | DVI+ | CTL | DVI+ | CTL
210338
DG Gel ABO/Rh (2D)
A DG Gel card that gives you full ABO/Rh forward and reverse with detection of partial DVI.
Configuration:
A | B | AB | DVI- | DVI+ | CTL | N | N
210198
DG Gel ABO/Rh (2DVI-)
Fully test ABO/Rh(D) forward and reverse grouping including double Rh(D) determination.
Configuration:
A | B | AB | DVI- | DVI- | CTL | N | N
210348
DG Gel ABO/Rh(2DVI-)+Kell
Enhance your testing with ABO/Rh(D) forward an reverse with dobule Rh(D) determination and kell typing in a single card.
Configuration:
A | B | DVI- | DVI- | K | CTL | N | N
210377
DG Gel T/S Poly
With DG Gel T/S Poly you can confirm ABO/Rh(D) type, test for antibodies common and rare, perform autocontrol and crossmatch quickly and safely in one workflow all on a single card.
Configuration:
A | B | DVI- | CTL | AHG | AHG | AHG | AHG
210374
DG Gel CT
A single card that gives you ABO/Rh(D) confirmation plus flexibility to run ABO/Rh(D) isogrup compatibility, antibody screening, crossmatch or autocontrol.
Configuration:
A | B | DVI+ | CTL | N | N | AHG | AHG
210346
DG Gel AB (x4)
Simply confirm four ABO blood groups in a single card.
Configuration:
A | B | A | B | A | B | A | B
210343
DG Gel Neutral
Enhance efficiency with the determination of eight antigen phenotypes or four A and B reverse grouping in a single card.
Configuration:
N | N | N | N | N | N | N | N
210375
DG Gel Neutral/Coombs
Enhance efficiency with the determination of eight antigen phenotypes or two A and B reverse grouping in a single card.
Configuration:
N | N | N | N | AHG | AHG | AHG | AHG
Test any number of ABO & Rh combinations with antisera that simplifies procedures. ABO and Rh antisera do not require incubation. They offer a drop, spin, and read process for rapid turnaround time.
Anti-A Mono-Type
213434
Monoclonal antisera to identify the A antigen on red cells in slide, tube, plate and microplate techniques in direct agglutination
Anti-B Mono-Type
213436
Monoclonal antisera to identify the B antigen on red cells in slide, tube, plate and microplate techniques in direct agglutination
Anti-A,B Mono-Type
213508
Monoclonal antisera to identify the A and B antigens on red cells in slide, tube, plate and microplate techniques in direct agglutination
Anti-A1 Lectin
213437
Lectin for the A1 blood group determination with the tube and gel technology
Anti-H Mono-Type
213633
Antisera to detect the H substance on the surface of the red cells with the tube and gel technology
IgM Anti-D (RUM-1) Mono-Type
213517
Antisera to type D antigen designed for the testing of patient blood
Name | Code | Description |
---|---|---|
Anti-A Mono-Type |
213434 |
Monoclonal antisera to identify the A antigen on red cells in slide, tube, plate and microplate techniques in direct agglutination |
Anti-B Mono-Type |
213436 |
Monoclonal antisera to identify the B antigen on red cells in slide, tube, plate and microplate techniques in direct agglutination |
Anti-A,B Mono-Type |
213508 |
Monoclonal antisera to identify the A and B antigens on red cells in slide, tube, plate and microplate techniques in direct agglutination |
Anti-A1 Lectin |
213437 |
Lectin for the A1 blood group determination with the tube and gel technology |
Anti-H Mono-Type |
213633 |
Antisera to detect the H substance on the surface of the red cells with the tube and gel technology |
IgM Anti-D (RUM-1) Mono-Type |
213517 |
Antisera to type D antigen designed for the testing of patient blood |
Reverse-Cyte A1,A2, B, O 5%
213383
Reagent Red Blood Cells 5% for the determination of the reverse group
Reverse-Cyte A1 5%
213388
Reagent Red Blood Cells 5% for the determination of the reverse group
Reverse-Cyte A2 5%
213389
Reagent Red Blood Cells 5% for the determination of the reverse group
Reverse-Cyte B 5%
213390
Reagent Red Blood Cells 5% for the determination of the reverse group
Reverse-Cyte O 5%
213391
Reagent Red Blood Cells 5% for the determination of the reverse group
Specific Albumin 22%
213422
Complementary solution to enhance the antigen-antibody reaction of compatibility testing, antibody screening, identification and titration
Specific Albumin 30%
213573
Complementary solution to enhance the antigen-antibody reaction of compatibility testing, antibody screening, identification and titration
Neutr-AB II
213424
Neutralization agent for immune anti-A and anti-B antibodies of the IgM class
Name | Code | Description |
---|---|---|
Reverse-Cyte A1,A2, B, O 5% |
213383 |
Reagent Red Blood Cells 5% for the determination of the reverse group |
Reverse-Cyte A1 5% |
213388 |
Reagent Red Blood Cells 5% for the determination of the reverse group |
Reverse-Cyte A2 5% |
213389 |
Reagent Red Blood Cells 5% for the determination of the reverse group |
Reverse-Cyte B 5% |
213390 |
Reagent Red Blood Cells 5% for the determination of the reverse group |
Reverse-Cyte O 5% |
213391 |
Reagent Red Blood Cells 5% for the determination of the reverse group |
Specific Albumin 22% |
213422 |
Complementary solution to enhance the antigen-antibody reaction of compatibility testing, antibody screening, identification and titration |
Specific Albumin 30% |
213573 |
Complementary solution to enhance the antigen-antibody reaction of compatibility testing, antibody screening, identification and titration |
Neutr-AB II |
213424 |
Neutralization agent for immune anti-A and anti-B antibodies of the IgM class |
Rh-Control Mono-Type
213397
Negative control to be used in parallel with monoclonal anti-D antisera tests
Dweak Control
213395
Weak positive control to be used in parallel with D typing tests
Essential II Control
213287
Quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique
Extended IV Control
213286
Quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique
Name | Code | Description |
---|---|---|
Rh-Control Mono-Type |
213397 |
Negative control to be used in parallel with monoclonal anti-D antisera tests |
Dweak Control |
213395 |
Weak positive control to be used in parallel with D typing tests |
Essential II Control |
213287 |
Quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique |
Extended IV Control |
213286 |
Quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique |
Enhance your ability to confirm the Rh(D) negative donors, rationalize the use of RhIG injections for pregnant women as well as the use of Rh(D) neg blood units for patients with BLOODchip ID RHD XT. Predict the RhD phenotype that cannot be resolved by serology and benefit from knowing the patient's or donor's genotype with a user-friendly streamlined workflow ready in just 4 hours and that only requires 30 minutes of hands-on time.
Accelerate pre-transfusion testing with Grifols' comprehensive typing, screening & identification assays.