Our solutions
Find the right method to perform this assay
This website is now available in Brazilian Portuguese, French, German, Italian, Polish, Portuguese and Spanish. You can choose your language in the top right corner.
INNOVATIVE DIAGNOSTIC SOLUTIONS
Transfuse with confidence while experiencing how simple and efficient screening for unexpected antibodies can be.
Predicting if patients have antibodies that could be incompatible with donor red blood cells is easy with Grifols solutions. A variety of reliable tests with increasing complexity mean you can create testing strategies from serology giving you control in gel and in tube.
Find the right method to perform this assay
Gel card technology
Conventional techniques
DG Gel cards are the original 8-column agglutination technology (CAT). With DG Gel you can screen blood quickly and safely for antibodies, common and rare. DG Gel cards are the solution to the flexibility you need with seamless for manual, semi-automated and fully automated.
Screening reagent red blood cells and DG Gel mean your laboratory can perform routine and complex testing with complete confidence.
210342
DG Gel Coombs
With DG Gel Coombs flexible testing is simple with one versatile card for many tests. Antibody screening & identification, crossmatch testing, autocontrol, red blood cell typing and direct coombs test can be performed on DG Gel Coombs card.
Configuration:
AHG | AHG | AHG | AHG | AHG | AHG | AHG | AHG
210343
DG Gel Neutral
Obtain loads of information using the 8 buffered gel medium to perform saline and enzymatic techniques to investigate unexpected antibodies such as screening, identification, crossmatch, and autocontrol.
Configuration:
N | N | N | N | N | N | N | N
210375
DG Gel Neutral/Coombs
Indirect and direct testing of saline and enzymatic tests, as well as antibody screening, identification, crossmatch testing, autocontrol and red blood cell typing all on one card gives you the flexibility to test your way.
Configuration:
N | N | N | N | AHG | AHG | AHG | AHG
210344
DG Gel Anti-IgG
DG Gel Anti-IgG gives you antibody detection and identification monospecific testing that fits your needs. Further characterization of the antibody is easy with DG Gel Anti-IgG.
Configuration:
IgG | IgG | IgG | IgG | IgG | IgG | IgG | IgG
210377
DG Gel T/S Poly
With DG Gel T/S Poly you can confirm ABO/Rh(D) type, test for antibodies common and rare, perform autocontrol and crossmatch quickly and safely in one workflow all on a single card.
Configuration:
A | B | DVI- | CTL | AHG | AHG | AHG | AHG
210374
DG Gel CT
A single card that gives you ABO/Rh(D) confirmation plus flexibility to run ABO/Rh(D) isogrup compatibility, antibody screening, crossmatch or autocontrol.
Configuration:
A | B | DVI+ | CTL | N | N | AHG | AHG
Serascan Diana Reagent Red Blood Cells (0.8%)
Test for antibodies common and rare with a flexible format of 2, 3 and 4 cells both untreated and papainized. Serascan Diana empowers your testing by offering antigens to major blood group systems in a format that provides the flexibility you need.
Sero-Cyte Reagent Red Blood Cells (0.8%)
Quickly perform antibody screens with Sero-Cyte Reagent Red Blood Cells. Available in Pool and 2 cell formats prepared from blood group O donors Sero-Cyte Reagent Red Blood Cells allow you to screen blood rapidly for antibodies common and rare.
Screen-Cyte (0.8%)
Screen-Cyte allows you to detect the majority of blood group antigens in homozygous form and detect dosage effect. Screen-Cyte 0.8% three group 0 selected cell suspensions are available untreated and papainized with at least one Cw, K, Kpa and Lua positive cell. Screen-Cyte Dia 0.8% contains at least one Dia, Cw and K.
Sero-Cyte Pool 0.8%
213634
3-cell screening panel
Sero-Cyte Pool Dia 0.8%
213687
Pool including Dia antigen
Serascan Diana 2
210204
2-cell screening panel
Sero-Cyte 0.8%
213589
2-cell screening panel
Serascan Diana 3
210206
3-cell screening panel
Screen-Cyte 0.8%
213590
3-cell screening panel
Screen-Cyte Dia 0.8%
213653
3-cell screening panel including Dia antigen
Serascan Diana 4
210208
4-cell screening panel
Serascan Diana Dia
210203
Dia antigen positive cell
Diego(a)-Cyte 0.8%
213802
Dia antigen positive cell
Mi(a)-Cyte 0.8%
213386
Mia antigen positive cell
Serascan Diana 2P
210205
Papainized 2-cell screening panel
Serascan Diana 3P
210207
Papainized 3-cell screening panel
Serascan Diana 4P
210209
Papainized 4-cell screening panel
Screen-Cyte P 0.8%
213665
Papainized 3-cell screening panel
Name | Code | Description |
---|---|---|
Sero-Cyte Pool 0.8% |
213634 |
3-cell screening panel |
Sero-Cyte Pool Dia 0.8% |
213687 |
Pool including Dia antigen |
Serascan Diana 2 |
210204 |
2-cell screening panel |
Sero-Cyte 0.8% |
213589 |
2-cell screening panel |
Serascan Diana 3 |
210206 |
3-cell screening panel |
Screen-Cyte 0.8% |
213590 |
3-cell screening panel |
Screen-Cyte Dia 0.8% |
213653 |
3-cell screening panel including Dia antigen |
Serascan Diana 4 |
210208 |
4-cell screening panel |
Serascan Diana Dia |
210203 |
Dia antigen positive cell |
Diego(a)-Cyte 0.8% |
213802 |
Dia antigen positive cell |
Mi(a)-Cyte 0.8% |
213386 |
Mia antigen positive cell |
Serascan Diana 2P |
210205 |
Papainized 2-cell screening panel |
Serascan Diana 3P |
210207 |
Papainized 3-cell screening panel |
Serascan Diana 4P |
210209 |
Papainized 4-cell screening panel |
Screen-Cyte P 0.8% |
213665 |
Papainized 3-cell screening panel |
Essential II Control
213287
Quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique
Extended IV Control
213286
Quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique
Bromelase 30
213578
Proteolytic enzyme used to supplement standard procedures by enhancing the reactivity of some antibodies and inhibit others in antibody screening, identification and crossmatch in gel and tube techniques
DG Fluid A
213679
Solutions used for the washing of the Grifols instruments' fluidic system
DG Fluid B
213678
Solutions used for the washing of the Grifols instruments' fluidic system
Name | Code | Description |
---|---|---|
Essential II Control |
213287 |
Quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique |
Extended IV Control |
213286 |
Quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique |
Bromelase 30 |
213578 |
Proteolytic enzyme used to supplement standard procedures by enhancing the reactivity of some antibodies and inhibit others in antibody screening, identification and crossmatch in gel and tube techniques |
DG Fluid A |
213679 |
Solutions used for the washing of the Grifols instruments' fluidic system |
DG Fluid B |
213678 |
Solutions used for the washing of the Grifols instruments' fluidic system |
Reagent Red Blood Cells in 3% that are a proven and reliable solution for every type of lab.
Whether you are utilizing conventional tube reagents for most of your testing or for resolving problematic cases, it is important to have a wide range of reagent red blood cells to meet your needs.
Anti-Human Globulin Mono-Type
213423
Polyspecific Coombs reagent to detect immunoglobulin and /or complement bound to red blood cells in direct and indirect antiglobulin tests
Anti-IgG
213559
Monospecific Coombs reagent for indirect antiglobulin tests to differentiate between IgG and complement sensitization
Sero-Cyte 3%
213384
2-cell screening panel
Screen-Cyte 3%
213385
3-cell screening panel
Screen-Cyte Dia 3%
213628
3-cell screening panel including Dia antigen
Diego(a)-Cyte 3%
213803
Dia antigen positive cell
Name | Code | Description |
---|---|---|
Anti-Human Globulin Mono-Type |
213423 |
Polyspecific Coombs reagent to detect immunoglobulin and /or complement bound to red blood cells in direct and indirect antiglobulin tests |
Anti-IgG |
213559 |
Monospecific Coombs reagent for indirect antiglobulin tests to differentiate between IgG and complement sensitization |
Sero-Cyte 3% |
213384 |
2-cell screening panel |
Screen-Cyte 3% |
213385 |
3-cell screening panel |
Screen-Cyte Dia 3% |
213628 |
3-cell screening panel including Dia antigen |
Diego(a)-Cyte 3% |
213803 |
Dia antigen positive cell |
Accelerate pre-transfusion testing with Grifols' comprehensive typing, screening & identification assays.