Procleix Panther System

Procleix Panther System

The Procleix Panther system combines full automation with versatility and smart operations for efficient NAT processing of blood and plasma. More donations are tested every year* with a Procleix system than any other. 

*Grifols, data on file, November 2022.

Main benefits

Smart design

Quickly access reportable results while maximizing lab space and minimizing operator interaction.

Simple operation

Streamline operations with quick and easy installation and training, user-friendly software and automated maintenance.

Versatile capabilities

Maximize workflow flexibility with continuous loading samples and full solution integrations.

Product specifications

Procleix Panther System

Product Detail

Sample throughput

Specification
  • Standard: 3.5 hr to first result; 5 results every 5 min thereafter
  • IDT: 275 results in 8 hr; 500 results in 12 hr

Sample capacity

Specification

  120 sample tubes (15 tubes per rack x 8 racks; with continuous sample loading ability)

Sample barcode types

Specification

  Code 39, Code 93, Code 128 (ISBT 128), NW7, Interleaved 2 of 5, Codabar, JAN-13, UPC

Reagent capacity

Specification
  • 1 reagent kit per lane
  • 4 lanes available to load any combination of assay reagents
  • 2000 test on-board capacity
  • Continuous reagent kit loading ability

Waste capacity

Specification

  Process 750 tests before unloading liquid and solid waste

Dimensions
(W x D x H)

Specification
  • Instrument: 122 x 81.5 x 175 cm (48 x 32 x 69 in)
  • UPS (optional): 21.4 x 41.0 x 32.5 cm (8.4 x 161.1 x 12.8 in)

    Note: touchscreen monitor adds 45.5 cm (18 in) to width

Clearance requirements

Specification
  • Width: 183 cm, minimum (6 ft; recommended space is 244 cm [8 ft])
  • Vertical: 198 cm (6.5 ft)
  • Front: 91.4 cm (3 ft)

   Note: touchscreen monitor adds 45.5 cm (18 in) to width

Weight

Specification
  • Instrument: 363 kg (800 lb)
  • UPS: 34.5 kg (76 lb)

Voltage

Specification
  • Instrument: 100-240 VAC (±10%; single phase)
  • UPS: 110 V-20 amp circuit (dedicated), specified to operate at a minimum of 15 amps (dedicated)
  • UPS: 220 V-10 amp circuit (dedicated), specified to operate at 7.5 amps (dedicated)

Frequency

Specification

  50/60 Hz, single phase

Power

Specification

  Instrument and ancillaries: 1400 W (peak; 13 amps @ 100 VAC, 5.4 amps @ 240 VAC)

Operational temperature

Specification

  15-30°C (59-86°F)

Operational humidity

Specification

  20-85% (relative, non-condensing)

Operational altitude

Specification

  ≤2000 m (6562 ft; above sea-level)

Heat dissipation

Specification

  550 W (1878 BTU/hr; during steady state)

Drain output

Specification

  None; waste fluids drain to removable containers

Noise output

Specification

  <70 dBA

Product Detail Specification

Sample throughput

  • Standard: 3.5 hr to first result; 5 results every 5 min thereafter
  • IDT: 275 results in 8 hr; 500 results in 12 hr

Sample capacity

  120 sample tubes (15 tubes per rack x 8 racks; with continuous sample loading ability)

Sample barcode types

  Code 39, Code 93, Code 128 (ISBT 128), NW7, Interleaved 2 of 5, Codabar, JAN-13, UPC

Reagent capacity

  • 1 reagent kit per lane
  • 4 lanes available to load any combination of assay reagents
  • 2000 test on-board capacity
  • Continuous reagent kit loading ability

Waste capacity

  Process 750 tests before unloading liquid and solid waste

Dimensions
(W x D x H)

  • Instrument: 122 x 81.5 x 175 cm (48 x 32 x 69 in)
  • UPS (optional): 21.4 x 41.0 x 32.5 cm (8.4 x 161.1 x 12.8 in)

    Note: touchscreen monitor adds 45.5 cm (18 in) to width

Clearance requirements

  • Width: 183 cm, minimum (6 ft; recommended space is 244 cm [8 ft])
  • Vertical: 198 cm (6.5 ft)
  • Front: 91.4 cm (3 ft)

   Note: touchscreen monitor adds 45.5 cm (18 in) to width

Weight

  • Instrument: 363 kg (800 lb)
  • UPS: 34.5 kg (76 lb)

Voltage

  • Instrument: 100-240 VAC (±10%; single phase)
  • UPS: 110 V-20 amp circuit (dedicated), specified to operate at a minimum of 15 amps (dedicated)
  • UPS: 220 V-10 amp circuit (dedicated), specified to operate at 7.5 amps (dedicated)

Frequency

  50/60 Hz, single phase

Power

  Instrument and ancillaries: 1400 W (peak; 13 amps @ 100 VAC, 5.4 amps @ 240 VAC)

Operational temperature

  15-30°C (59-86°F)

Operational humidity

  20-85% (relative, non-condensing)

Operational altitude

  ≤2000 m (6562 ft; above sea-level)

Heat dissipation

  550 W (1878 BTU/hr; during steady state)

Drain output

  None; waste fluids drain to removable containers

Noise output

  <70 dBA