ABO/Rh(D) Confirmation (CE Approved)
Trust through verification: confirm your blood group type results reliably and efficiently.
ABO/Rh(D) Confirmation
There are no shortcuts to patient safety. Test reliably and efficiently for your lab’s needs whether you test in gel or tube. A variety of typing confirmation solutions make it easy to confirm previously typed ABO & Rh groups, so you deliver on time.
Our solutions
Find the right method to perform this assay
Gel card technology
The flexibility of the DG Gel card facilitates seamless upgrades when your lab’s needs change
Organize your testing on a single card or in a single microwell and increase your lab’s efficiency whether you test gel manually, or with semi- or full automation. With an original 8-well format DG Gel cards give you flexibility to confirm ABO & Rh the way you work with the testing configuration you need.
DG Gel Cards for this assay
Quality Controls and complementary solutions for this assay:
- Code
213287
- Description
Quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique
- Code
213286
- Description
Quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique
- Code
210354
- Description
Reagent used for suspending red blood cells and diluting plasma or serum samples
- Code
213797
- Description
Solution for cleaning the probes of Grifols instruments
- Code
213679
- Description
Solutions used for the washing of the Grifols instruments' fluidic system
- Code
213678
- Description
Solutions used for the washing of the Grifols instruments' fluidic system
| Name | Code | Description |
|---|---|---|
|
Essential II Control |
213287 |
Quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique |
|
Extended IV Control |
213286 |
Quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique |
|
DG Gel Sol |
210354 |
Reagent used for suspending red blood cells and diluting plasma or serum samples |
|
DG Clean |
213797 |
Solution for cleaning the probes of Grifols instruments |
|
DG Fluid A |
213679 |
Solutions used for the washing of the Grifols instruments' fluidic system |
|
DG Fluid B |
213678 |
Solutions used for the washing of the Grifols instruments' fluidic system |
Conventional-techniques
Conventional reagents that are a proven and reliable solution for every type of lab
Whether you are utilizing conventional tube reagents for most of your testing or for resolving problematic cases, it is important to have a wide range of conventional reagents to meet your needs. Test any number of ABO & Rh combinations with antisera that simplifies procedures for conventional tube serology techniques.
Reagents for this assay
- Code
210929
- Description
Monoclonal antisera to identify the A antigen on red cells using tube technique in direct agglutination
- Code
210931
- Description
Monoclonal antisera to identify the B antigen on red cells using tube technique in direct agglutination
- Code
210930
- Description
Monoclonal antisera to identify the A and B antigens on red cells using tube technique in direct agglutination
- Code
215520
- Description
Monoclonal antisera to identify the H antigen on red cells using tube technique in direct agglutination
- Code
210932
- Description
Monoclonal antisera to identify the RhD antigen on red cells using tube technique in direct agglutination
- Code
210922
- Description
Mix of IgM and IgG antisera to identify the RhD antigen including the detection of most types of weak Rh(D) and partial DVI using tube technique
- Code
210935
- Description
Polyspecific Coombs reagent to detect immunoglobulin and /or complement bound to red blood cells in direct and indirect antiglobulin tests
- Code
213559
- Description
Monospecific Coombs reagent for indirect antiglobulin tests to differentiate between IgG and complement sensitization
| Name | Code | Description |
|---|---|---|
|
Anti-A Mono-Type |
210929 |
Monoclonal antisera to identify the A antigen on red cells using tube technique in direct agglutination |
|
Anti-B Mono-Type |
210931 |
Monoclonal antisera to identify the B antigen on red cells using tube technique in direct agglutination |
|
Anti-A,B Mono-Type |
210930 |
Monoclonal antisera to identify the A and B antigens on red cells using tube technique in direct agglutination |
|
Anti-H Mono-Type |
215520 |
Monoclonal antisera to identify the H antigen on red cells using tube technique in direct agglutination |
|
Anti-D IgM Mono-Type |
210932 |
Monoclonal antisera to identify the RhD antigen on red cells using tube technique in direct agglutination |
|
Anti-D Combi Mono-Type |
210922 |
Mix of IgM and IgG antisera to identify the RhD antigen including the detection of most types of weak Rh(D) and partial DVI using tube technique |
|
Anti-Human Globulin Polyspecific |
210935 |
Polyspecific Coombs reagent to detect immunoglobulin and /or complement bound to red blood cells in direct and indirect antiglobulin tests |
|
Anti-IgG |
213559 |
Monospecific Coombs reagent for indirect antiglobulin tests to differentiate between IgG and complement sensitization |
Quality Controls and complementary solutions for this assay:
- Code
213394
- Description
Positive control for antiglobulin tests based on red cells sensitized with humnan IgG antibodies
- Code
210933
- Description
Negative quality control reagent for parallel testing with Grifols monoclonal blood grouping antisera including ABO, Rh (C, c, E, e), Kidd, and Lewis; presentation: 6 × 5 mL.
- Code
210934
- Description
Negative quality control reagent for parallel testing with Grifols monoclonal blood grouping antisera including ABO, Rh (C, c, E, e), Kidd, and Lewis; presentation: 1 × 5 mL.
- Code
213561
- Description
Dual use weak positive control with a confirmed weak expression of the RhD antigen to be used in parallel with D typing tests either using DG Gel System or tube technique
- Code
213287
- Description
Dual use quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique
- Code
213286
- Description
Dual use quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique
| Name | Code | Description |
|---|---|---|
|
Coombs Control |
213394 |
Positive control for antiglobulin tests based on red cells sensitized with humnan IgG antibodies |
|
Antisera Control |
210933 |
Negative quality control reagent for parallel testing with Grifols monoclonal blood grouping antisera including ABO, Rh (C, c, E, e), Kidd, and Lewis; presentation: 6 × 5 mL. |
|
Antisera Control |
210934 |
Negative quality control reagent for parallel testing with Grifols monoclonal blood grouping antisera including ABO, Rh (C, c, E, e), Kidd, and Lewis; presentation: 1 × 5 mL. |
|
Weak D Control |
213561 |
Dual use weak positive control with a confirmed weak expression of the RhD antigen to be used in parallel with D typing tests either using DG Gel System or tube technique |
|
Essential II Control |
213287 |
Dual use quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique |
|
Extended IV Control |
213286 |
Dual use quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique |
Downloadable resources
Explore other Blood Typing Tests
Accelerate pre-transfusion testing with Grifols' comprehensive typing, screening & identification assays.