Antibody Identification

Antibody Identification

If unexpected antibodies are detected in a sample, rapid and safe identification is essential for your lab. 

When Antibody identification is needed as part of your routine pretransfusion testing Grifols has everything you need.

Our solutions

Find the right method to perform this assay

Gel card technology

Learn more

Conventional techniques

Learn more

Gel card technology

DG Gel cards organize your antibody investigation and make testing efficient no matter the size of your lab

DG Gel cards are the original 8-column agglutination technology (CAT). DG Gel cards paired with high-quality reagents facilitate efficient antibody identification in any workflow. Screen blood quickly and safely for antibodies, common and rare and in all testing configurations. DG Gel cards and wide selection of rRBC deliver efficient results for every lab and can grow as your volume increases.

DG Gel Card for Antibody Identification (CE)

DG Gel Cards for this assay

210342
DG Gel Coombs

With DG Gel Coombs flexible testing is simple with one versatile card for many tests. Antibody screening & identification, crossmatch testing, autocontrol, red blood cell typing and direct coombs test can be performed on DG Gel Coombs card.

Configuration:
AHG | AHG | AHG | AHG | AHG | AHG | AHG | AHG

210343
DG Gel Neutral

Obtain loads of information using the 8 buffered gel medium to perform saline and enzymatic techniques to investigate unexpected antibodies such as screening, identification, crossmatch, and autocontrol. 

Configuration:
N | N | N | N | N | N | N | N

210375
DG Gel Neutral/Coombs

Indirect and direct testing of saline and enzymatic tests, as well as antibody screening, identification, crossmatch testing, auto control and red blood cell typing all on one card gives you the flexibility to test your way.

Configuration:
N | N | N | N | AHG | AHG | AHG | AHG

210344
DG Gel Anti-IgG

DG Gel Anti-IgG gives you antibody detection and identification monospecific testing that fits your needs. Further characterization of the antibody is easy with DG Gel Anti-IgG. 

Configuration:
IgG | IgG | IgG | IgG | IgG | IgG | IgG | IgG

Reagents for this assay

Identisera Diana Red Blood Cells

Identify common and rare clinically significant antibodies with a flexible format of 11 or 15 ready-to-use red blood cells. Identisera Diana panels are available untreated and papainized so you can mix and match rRBCs to optimize your analysis. 

Data-Cyte Plus 0.8% Red Blood Cells

Identify common and rare clinically significant antibodies with a flexible format of 11, 12, 15 or 16 ready-to-use red blood cells. Data-Cyte Plus 0.8% panels are available untreated and papainized so you can mix and match rRBCs to optimize your analysis. 

Name

Identisera Diana

Code

210210

Description

11-cell identification panel

Identisera Diana Extend

Code

210212

Description

4-cell identification panel to be added to Identisera Diana

Data-Cyte Plus 0.8%

Code

213587

Description

11-cell identification panel

Data-Cyte Plus Dia 0.8%

Code

213627

Description

12-cell identification panel including Dia antigen

Data-Cyte Extend 0.8%

Code

213685

Description

4-cell panel of 4 Rh(D) negative donors to be used alone or complementing Data-Cyte Plus 0.8% panels

Diego(a)-Cyte 0.8%

Code

213802

Description

Dia antigen positive cell

Mi(a)-Cyte 0.8% 

Code

213386

Description

Mia antigen positive cell

Identisera Diana P

Code

210211

Description

Papainized 11-cell identification panel

Identisera Diana Extend P

Code

210213

Description

Papainized 4-cell identification panel to be added to Identisera Diana P

Data-Cyte Plus P 0,8%

Code

213661

Description

Papainized 11-cell identification panel

Name Code Description

Identisera Diana

210210

11-cell identification panel

Identisera Diana Extend

210212

4-cell identification panel to be added to Identisera Diana

Data-Cyte Plus 0.8%

213587

11-cell identification panel

Data-Cyte Plus Dia 0.8%

213627

12-cell identification panel including Dia antigen

Data-Cyte Extend 0.8%

213685

4-cell panel of 4 Rh(D) negative donors to be used alone or complementing Data-Cyte Plus 0.8% panels

Diego(a)-Cyte 0.8%

213802

Dia antigen positive cell

Mi(a)-Cyte 0.8% 

213386

Mia antigen positive cell

Identisera Diana P

210211

Papainized 11-cell identification panel

Identisera Diana Extend P

210213

Papainized 4-cell identification panel to be added to Identisera Diana P

Data-Cyte Plus P 0,8%

213661

Papainized 11-cell identification panel

Quality Controls and complementary solutions for this assay:

Name

Essential II Control

Code

213287

Description

Quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique

Extended IV Control

Code

213286

Description

Quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique

Bromelase 30

Code

213578

Description

Proteolytic enzyme used to supplement standard procedures by enhancing the reactivity of some antibodies and inhibit others in antibody screening, identification and crossmatch in gel and tube techniques

DG Fluid A

Code

213679

Description

Solutions used for the washing of the Grifols instruments' fluidic system

DG Fluid B

Code

213678

Description

Solutions used for the washing of the Grifols instruments' fluidic system

Name Code Description

Essential II Control

213287

Quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique

Extended IV Control

213286

Quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique

Bromelase 30

213578

Proteolytic enzyme used to supplement standard procedures by enhancing the reactivity of some antibodies and inhibit others in antibody screening, identification and crossmatch in gel and tube techniques

DG Fluid A

213679

Solutions used for the washing of the Grifols instruments' fluidic system

DG Fluid B

213678

Solutions used for the washing of the Grifols instruments' fluidic system

Conventional techniques

Conventional reagents that are a proven and reliable solution for every type of lab

Whether you are utilizing conventional tube reagents for most of your testing or for resolving problematic cases, it is important to have a wide range of reagent red blood cells and antisera to meet your needs.

Simplifying antibody identification procedures for conventional serology is easy with our extensive range of reagents.

 

Antisera (blood serum)

Reagents for this assay

Name

Anti-Human Globulin Mono-Type

Code

213423

Description

Polyspecific Coombs reagent to detect immunoglobulin and /or complement bound to red blood cells in direct and indirect antiglobulin tests

Anti-IgG

Code

213559

Description

Monospecific Coombs reagent for indirect antiglobulin tests to differentiate between IgG and complement sensitization

Data-Cyte Plus 3%

Code

213392

Description

11-cell identification panel 

Data-Cyte Plus Dia 3%

Code

213626

Description

12-cell identification panel including Dia antigen

Diego(a)-Cyte 3%

Code

213803

Description

Dia antigen positive cell

Name Code Description

Anti-Human Globulin Mono-Type

213423

Polyspecific Coombs reagent to detect immunoglobulin and /or complement bound to red blood cells in direct and indirect antiglobulin tests

Anti-IgG

213559

Monospecific Coombs reagent for indirect antiglobulin tests to differentiate between IgG and complement sensitization

Data-Cyte Plus 3%

213392

11-cell identification panel 

Data-Cyte Plus Dia 3%

213626

12-cell identification panel including Dia antigen

Diego(a)-Cyte 3%

213803

Dia antigen positive cell

Quality Controls and complementary solutions for this assay:

Name

Coombs Control

Code

213394

Description

Positive control for antiglobulin tests based on red cells sensitized with humnan IgG antibodies

Essential II Control

Code

213287

Description

Quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique

Extended IV Control

Code

213286

Description

Quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique

Specific Albumin 22%

Code

213422

Description

Complementary solution to enhance the antigen-antibody reaction of compatibility testing, antibody screening, identification and titration

Specific Albumin 30%

Code

213573

Description

Complementary solution to enhance the antigen-antibody reaction of compatibility testing, antibody screening, identification and titration

ENLISST-II

Code

213577

Description

Low Ionic Strength Solution used to enhance antigen-antibody reactions in tube procedures such as compatibility testing, antibody screening and identification

Bromelase 30

Code

213578

Description

Proteolytic enzyme used to supplement standard procedures by enhancing the reactivity of some antibodies and inhibit others in antibody screening, identification and crossmatch in gel and tube techniques

Name Code Description

Coombs Control

213394

Positive control for antiglobulin tests based on red cells sensitized with humnan IgG antibodies

Essential II Control

213287

Quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique

Extended IV Control

213286

Quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique

Specific Albumin 22%

213422

Complementary solution to enhance the antigen-antibody reaction of compatibility testing, antibody screening, identification and titration

Specific Albumin 30%

213573

Complementary solution to enhance the antigen-antibody reaction of compatibility testing, antibody screening, identification and titration

ENLISST-II

213577

Low Ionic Strength Solution used to enhance antigen-antibody reactions in tube procedures such as compatibility testing, antibody screening and identification

Bromelase 30

213578

Proteolytic enzyme used to supplement standard procedures by enhancing the reactivity of some antibodies and inhibit others in antibody screening, identification and crossmatch in gel and tube techniques

Explore other Blood Typing Tests

Accelerate pre-transfusion testing with Grifols' comprehensive typing, screening & identification assays.