Antibody Screening (CE)

Antibody Screening

Predicting if patients have antibodies that could be incompatible with donor red blood cells is easy with Grifols solutions. A variety of reliable tests with increasing complexity mean you can create testing strategies from serology giving you control in gel and in tube. 

Our solutions

Find the right method to perform this assay

Gel card technology

Learn more

Conventional techniques

Learn more

Gel card technology

0.8% rRBCs organize your screening and make testing efficient no matter the size of your lab

DG Gel cards are the original 8-column agglutination technology (CAT). With DG Gel you can screen blood quickly and safely for antibodies, common and rare. DG Gel cards are the solution to the flexibility you need with seamless for manual, semi-automated and fully automated. 

Screening reagent red blood cells and DG Gel mean your laboratory can perform routine and complex testing with complete confidence.

DG Gel Card for Antibody Screening (CE)

DG Gel Cards for this assay

210342
DG Gel Coombs

With DG Gel Coombs flexible testing is simple with one versatile card for many tests. Antibody screening & identification, crossmatch testing, autocontrol, red blood cell typing and direct coombs test can be performed on DG Gel Coombs card.

Configuration:
AHG | AHG | AHG | AHG | AHG | AHG | AHG | AHG

210343
DG Gel Neutral

Obtain loads of information using the 8 buffered gel medium to perform saline and enzymatic techniques to investigate unexpected antibodies such as screening, identification, crossmatch, and autocontrol. 

Configuration:
N | N | N | N | N | N | N | N

210375
DG Gel Neutral/Coombs

Indirect and direct testing of saline and enzymatic tests, as well as antibody screening, identification, crossmatch testing, autocontrol and red blood cell typing all on one card gives you the flexibility to test your way.

Configuration:
N | N | N | N | AHG | AHG | AHG | AHG

210344
DG Gel Anti-IgG

DG Gel Anti-IgG gives you antibody detection and identification monospecific testing that fits your needs. Further characterization of the antibody is easy with DG Gel Anti-IgG. 

Configuration:
IgG | IgG | IgG | IgG | IgG | IgG | IgG | IgG

210377
DG Gel T/S Poly

With DG Gel T/S Poly you can confirm ABO/Rh(D) type, test for antibodies common and rare, perform autocontrol and crossmatch quickly and safely in one workflow all on a single card. 

Configuration:
A | B | DVI- | CTL | AHG | AHG | AHG | AHG

210374
DG Gel CT

A single card that gives you ABO/Rh(D) confirmation plus flexibility to run ABO/Rh(D) isogrup compatibility, antibody screening, crossmatch or autocontrol. 

Configuration:
A | B | DVI+ | CTL | N | N | AHG | AHG

Reagents for this assay

Serascan Diana Reagent Red Blood Cells (0.8%)

Test for antibodies common and rare with a flexible format of 2, 3 and 4 cells both untreated and papainized. Serascan Diana empowers your testing by offering antigens to major blood group systems in a format that provides the flexibility you need.

Sero-Cyte Reagent Red Blood Cells (0.8%)

Quickly perform antibody screens with Sero-Cyte Reagent Red Blood Cells. Available in Pool and 2 cell formats prepared from blood group O donors Sero-Cyte Reagent Red Blood Cells allow you to screen blood rapidly for antibodies common and rare.

Screen-Cyte (0.8%)

Screen-Cyte allows you to detect the majority of blood group antigens in homozygous form and detect dosage effect. Screen-Cyte 0.8% three group 0 selected cell suspensions are available untreated and papainized with at least one Cw, K, Kpa and Lua positive cell. Screen-Cyte Dia 0.8% contains at least one Dia, Cw and K.

Name

Sero-Cyte Pool 0.8%

Code

213634

Description

3-cell screening panel

Sero-Cyte Pool Dia 0.8%

Code

213687

Description

Pool including Dia antigen

Serascan Diana 2

Code

210204

Description

2-cell screening panel

Sero-Cyte 0.8%

Code

213589

Description

2-cell screening panel

Serascan Diana 3

Code

210206

Description

3-cell screening panel

Screen-Cyte 0.8%

Code

213590

Description

3-cell screening panel

Screen-Cyte Dia 0.8%

Code

213653

Description

3-cell screening panel including Dia antigen

Serascan Diana 4

Code

210208

Description

4-cell screening panel

Serascan Diana Dia

Code

210203

Description

Dia antigen positive cell

Diego(a)-Cyte 0.8%

Code

213802

Description

Dia antigen positive cell

Mi(a)-Cyte 0.8%

Code

213386

Description

Mia antigen positive cell

Serascan Diana 2P

Code

210205

Description

Papainized 2-cell screening panel

Serascan Diana 3P

Code

210207

Description

Papainized 3-cell screening panel

Serascan Diana 4P

Code

210209

Description

Papainized 4-cell screening panel

Screen-Cyte P 0.8%

Code

213665

Description

Papainized 3-cell screening panel

Name Code Description

Sero-Cyte Pool 0.8%

213634

3-cell screening panel

Sero-Cyte Pool Dia 0.8%

213687

Pool including Dia antigen

Serascan Diana 2

210204

2-cell screening panel

Sero-Cyte 0.8%

213589

2-cell screening panel

Serascan Diana 3

210206

3-cell screening panel

Screen-Cyte 0.8%

213590

3-cell screening panel

Screen-Cyte Dia 0.8%

213653

3-cell screening panel including Dia antigen

Serascan Diana 4

210208

4-cell screening panel

Serascan Diana Dia

210203

Dia antigen positive cell

Diego(a)-Cyte 0.8%

213802

Dia antigen positive cell

Mi(a)-Cyte 0.8%

213386

Mia antigen positive cell

Serascan Diana 2P

210205

Papainized 2-cell screening panel

Serascan Diana 3P

210207

Papainized 3-cell screening panel

Serascan Diana 4P

210209

Papainized 4-cell screening panel

Screen-Cyte P 0.8%

213665

Papainized 3-cell screening panel

Quality Controls and complementary solutions for this assay:

Name

Essential II Control

Code

213287

Description

Quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique

Extended IV Control

Code

213286

Description

Quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique

Bromelase 30

Code

213578

Description

Proteolytic enzyme used to supplement standard procedures by enhancing the reactivity of some antibodies and inhibit others in antibody screening, identification and crossmatch in gel and tube techniques

DG Fluid A

Code

213679

Description

Solutions used for the washing of the Grifols instruments' fluidic system

DG Fluid B

Code

213678

Description

Solutions used for the washing of the Grifols instruments' fluidic system

Name Code Description

Essential II Control

213287

Quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique

Extended IV Control

213286

Quality control for the determination of the ABO, Rhesus and Kell antigens, the appropriate ABO blood group antibodies, and the detection of unexpected antibodies in both antiglobulin and enzyme techniques either using DG Gel System or tube technique

Bromelase 30

213578

Proteolytic enzyme used to supplement standard procedures by enhancing the reactivity of some antibodies and inhibit others in antibody screening, identification and crossmatch in gel and tube techniques

DG Fluid A

213679

Solutions used for the washing of the Grifols instruments' fluidic system

DG Fluid B

213678

Solutions used for the washing of the Grifols instruments' fluidic system

Conventional techniques

Conventional reagents that are a proven and reliable solution for every type of lab

Reagent Red Blood Cells in 3% that are a proven and reliable solution for every type of lab.

Whether you are utilizing conventional tube reagents for most of your testing or for resolving problematic cases, it is important to have a wide range of reagent red blood cells to meet your needs.

Reagents for this assay

Name

Anti-Human Globulin Mono-Type

Code

213423

Description

Polyspecific Coombs reagent to detect immunoglobulin and /or complement bound to red blood cells in direct and indirect antiglobulin tests

Anti-IgG

Code

213559

Description

Monospecific Coombs reagent for indirect antiglobulin tests to differentiate between IgG and complement sensitization

Sero-Cyte 3%

Code

213384

Description

2-cell screening panel

Screen-Cyte 3%

Code

213385

Description

3-cell screening panel

Screen-Cyte Dia 3%

Code

213628

Description

3-cell screening panel including Dia antigen

Diego(a)-Cyte 3%

Code

213803

Description

Dia antigen positive cell

Name Code Description

Anti-Human Globulin Mono-Type

213423

Polyspecific Coombs reagent to detect immunoglobulin and /or complement bound to red blood cells in direct and indirect antiglobulin tests

Anti-IgG

213559

Monospecific Coombs reagent for indirect antiglobulin tests to differentiate between IgG and complement sensitization

Sero-Cyte 3%

213384

2-cell screening panel

Screen-Cyte 3%

213385

3-cell screening panel

Screen-Cyte Dia 3%

213628

3-cell screening panel including Dia antigen

Diego(a)-Cyte 3%

213803

Dia antigen positive cell

Explore other Blood Typing Tests

Accelerate pre-transfusion testing with Grifols' comprehensive typing, screening & identification assays.